| SPECIFICATION
Series Name |
VKU |
Nominal Cooling Capacity (tonnage) |
2 |
Star Rating |
3 star |
(Rated) Voltage/Frequency/Phase |
230 V / 50Hz / Single |
Cooling Capacity (Watt)(Min~Max) |
6200(2184.0-6382.8) |
Cooling Capacity (BTU/hr) |
21155 |
Rated Cooling Capacity (50% Load) (Watt) |
3100 |
Cooling Rated Power Input (Watt) |
2000 |
Cooling Capacity (BTU/hr)(Min~Max) |
21155(7452-21779) |
Cooling Power Input (50% Load) (Watt) |
727 |
ISEER |
3.95 |
Electricity Consumed In 1600 Hours. (Units/Year) |
1215.67 |
Nominal Current (Cooling)(Amps) |
8.7 |
Air Flow Volume (Wet CFM) (High / Medium / Low) |
705/670/507/378 |
Noise Level Indoor (dB(a)) (High/ Medium/ Low) |
48.8/43.6/39 |
Moisture Removal (Litres/Hour) |
2.17 |
Compressor Type |
Inverter Rotary |
Acoustic Jacket On Compressor |
Yes |
Refrigerant Quantity(Kg) |
0.83 |
Remote |
LCD Remote with Display |
Night Glow Function On Remote Buttons |
No |
Input Power Supply |
IDU |
Net Weight IDU (kg) |
12 |
Net ODU Dimensions (Width X Depth X Height) (mm) |
888.4 x 367 x 581.5 |
Noise Level Outdoor (dB(a)) |
60 |
Gross IDU Weight (kg) |
13.1 |
Gross ODU Weight (kg) |
37 |
Suction Tube Size Outer Diameter Inch (mm) |
1/2" (12.7mm) |
Liquid Tube Size Outer Diameter Inch (mm) |
1/4" (6.35mm) |
Max Piping Capability Total (metre) |
15 |
Max Piping Capability Vertical (metre) |
10 |
Refrigerant Additional Charge Beyond 4M (g/m) |
15 |
Power Supply to ODU Source(Core/Gauge) |
4C * 1.5sqmm |
Power Supply to IDU Source(Core/Gauge) |
3C * 1.5sqmm |
Remote Battery Type |
AAA |
Product Title |
VKU | INVERTER AC | 3 STAR | 2 TON |
Features Refrigerant |
R32 |
Features Condenser Type |
100% Copper |
Air Conditioner Technology |
Inverter |
Country of Origin |
India |
| DESCRIPTION
Highlights :
1 ton Capacity 2star rated
LED Panel Display
Remote Control, Timer
Turbo Mode, Sleep Mode
Dust Filter
Description :
SPECIFICATIONS:
General
AC Type Split
Type Split Fix Speed
Condenser Coil Copper
Model Name KAS-F12BAFC
Brand KELVINATOR
In the box IDU, ODU, User Manual
Star Rating 2 Star BEE Rating
Capacity in Tons 1 Ton
Dimensions
Indoor W x H x D 99.7 cm x 34.3 cm x 20.5 cm
Indoor Unit Weight 12.1 kg
Outdoor W x H x D 87 cm x 56 cm x 36.5 cm
Outdoor Unit Weight 26.7 kg
Performance Features
Turbo Mode Yes
Panel Display Yes
Air Flow and Filter Features
Auto Air Swing Yes
Dust Filter Yes
Other Filter Features
Convenience Features
Auto Restart Yes
Sleep Mode Yes
Services
Installation Details As Per the brand policy
Warranty
Warranty Summary As per the company Warranty. | SPECIFICATION
Series Name |
YN |
Nominal Cooling Capacity (tonnage) |
2 |
Star Rating |
3 star |
(Rated) Voltage/Frequency/Phase |
230 V / 50Hz / Single |
Cooling Capacity (Watt)(Min~Max) |
6350 (1772 ~ 6624) |
Cooling Capacity (BTU/hr) |
21666 |
Rated Cooling Capacity (50% Load) (Watt) |
3175 |
Cooling Rated Power Input (Watt) |
2025 |
Cooling Capacity (BTU/hr)(Min~Max) |
21666 (6046 ~ 22601) |
Cooling Power Input (50% Load) (Watt) |
770 |
ISEER |
3.9 |
Electricity Consumed In 1600 Hours. (Units/Year) |
1261.37 |
Nominal Current (Cooling)(Amps) |
9.17 |
Air Flow Volume (Wet CFM) (High / Medium / Low) |
576/501/399 |
Noise Level Indoor (dB(a)) (High/ Medium/ Low) |
46.8/43.7/37.7 |
Moisture Removal (Litres/Hour) |
2 |
Compressor Type |
Inverter Rotary |
Acoustic Jacket On Compressor |
Yes |
Refrigerant Quantity(Kg) |
0.9 |
Ambient Temp (Cooling) (degree C) |
52 |
Remote |
LCD Remote with Display |
Night Glow Function On Remote Buttons |
Yes |
Net IDU(Product) Dimension (mm) |
1110 x 335 x 215 |
Input Power Supply |
Indoor Unit |
Net Weight IDU (kg) |
15 |
Net ODU Dimensions (Width X Depth X Height) (mm) |
888.4 x 581.5 x 367 |
Net Weight ODU (kg) |
31.5 |
Noise Level Outdoor (dB(a)) |
60 |
Gross IDU Weight (kg) |
18 |
Gross ODU Weight (kg) |
37 |
Suction Tube Size Outer Diameter Inch (mm) |
5/8" (15.88mm) |
Liquid Tube Size Outer Diameter Inch (mm) |
1/4" (6.35mm) |
Max Piping Capability Total (metre) |
15 |
Max Piping Capability Vertical (metre) |
10 |
Refrigerant Additional Charge Beyond 4M (g/m) |
15 |
Power Supply to ODU Source(Core/Gauge) |
4C * 2.5sqmm |
Power Supply to IDU Source(Core/Gauge) |
3C * 2.5sqmm |
Remote Battery Type |
AAA |
Product Title |
YNU | INVERTER AC | 3 STAR | 2 TON |
Features Refrigerant |
R32 |
Features Condenser Type |
100% Copper |
Air Conditioner Technology |
Inverter |
Category |
3 Star |
Country of Origin |
India |
|
DESCRIPTION
Highlights :
- 1.5 Ton
- 3 Star
- Inverter
- Copper Condenser
SPECIFICATIONS
General |
AC Type |
Split |
Type |
Spilit Invertor AC |
Compressor |
Inverter Compressor |
Condenser Coil |
Copper |
Cooling Capacity |
5050 |
Model Name |
KAS-I18CPYG |
Brand |
KELVINATOR |
In the box |
Air Conditioners, User manaual |
Star Rating |
3 Star BEE Rating |
Capacity in Tons |
1.5 Ton |
Dimensions |
Indoor W x H x D |
1000 x 230 x 295 mm |
Indoor Unit Weight |
11 kg |
Outdoor W x H x D |
781 x 281 x 557 mm |
Outdoor Unit Weight |
23 kg |
Performance Features |
ISEER |
3.86 |
Indoor Noise Level |
49 / 44 / 42 / 41 |
Power Features |
Power Requirement |
AC 230 / 50 Hz |
Warranty |
Warranty Summary |
As per the company Warranty. |
|
DESCRIPTION
Highlights :
- 1 Ton
- 3 Star
- Inverter
- Copper Condenser
SPECIFICATIONS
General |
AC Type |
Split |
Type |
Spilit Invertor AC |
Compressor |
Inverter Compressor |
Condenser Coil |
Copper |
Cooling Capacity |
3400 |
Model Name |
KAS-I12CPYG |
Brand |
KELVINATOR |
In the box |
Air Conditioners, User manaual |
Star Rating |
3 Star BEE Rating |
Capacity in Tons |
1 Ton |
Dimensions |
Indoor W x H x D |
800 x 230 x295 mm |
Indoor Unit Weight |
9.3 kg |
Outdoor W x H x D |
780 x 241 x 557 mm |
Outdoor Unit Weight |
22.5 kg |
Performance Features |
ISEER |
3.88 |
Indoor Noise Level |
44 / 40 / 38 / 37 |
Power Features |
Power Requirement |
AC 230 / 50 Hz |
Warranty |
Warranty Summary |
As per the company Warranty. |
|